LabSat3 Technical specificiation

Table of contents
 

LabSat 3

Single constellation

LabSat 3

Dual constellation

LabSat 3

Triple constellation

Constellation

GPS, Galileo, SBAS, QZSS, GLONASS or BeiDou GPS, Galileo, SBAS, QZSS, GLONASS or BeiDou GPS, Galileo, SBAS, QZSS, GLONASS or BeiDou

Output Signal Level

Adjustable from  -73dBm to -103dBm Adjustable from -73dBm to -103dBm

Adjustable from -73dBm to

 -103dBm

RF Constellations

1 2 3

RF Constellation

Centre Frequency

1575.4/1602.00/1561.098/MHz

GPS&GALILEO/GLONASS/Beidou

Number of Satellites Observed

All in view

Sampling frequency

16.368 MHz

Bandwidth

9.66 MHz

Quantisation

1 constellation at 1-bit I&Q or at 2-bit I&Q 2 constellations at 1-bit I&Q or 1 constellation at 2-bit I&Q 2/3 constellations at 1-bit I&Q or 1 constellation at 2-bit I&Q

Data Format

I & Q

User Control

6 Button Membrane Keypad

Display

Backlit LCD Dotmatrix

Additional Logging

1 channel Digitized CAN, RS232 or Digital or 2 channels of log file CAN  (licence upgrade) 2 channels of CAN, RS232, Digital or 2 channels of log file CAN + 1/2 channels of digital (RS232/Digi) 2 channels of CAN, RS232, Digital or 2 channels of log file CAN + 1/2 channels of digital (RS232/Digi)

Removable Battery Pack

Record & Replay version only Both versions Both versions

Battery Type

Varta Easypack Li_Polymer 2260mAh

Media Storage Included

32GB SD Card & 1TB USB HDD

SD Card Media

Class 10 max size 128GB (FAT32)

Active Antenna Voltage Supply

2.80 – 3.0 volts

Reference Oscillator

16.368 MHz Temperature controlled +/- 2.5 ppm or OCXO option +/- 0.3 ppm
Operating Voltage 8V to 30VDC
Power Consumption  Power < 16W
Size 167mm x 128mm x 43mm
Weight 960g with battery (910g without battery)
Operating Temperature -20°C to +60°C Note: Battery will not charge below 0°C or above +45°C (charger shuts down outside this range). Unit will shut down outside operating temperature range.
Storage Temperature –20°C to +60°C Note: Battery will discharge whilst in storage and discharge rate will increase at higher storage temperatures.

 

 

LabSat 3 dimensions

 

The LabSat 3 dimensions in millimetres. 