Skip to main content
RACELOGIC Support Centre

17 - PB/DB - Technical Specification

Velocity
Accuracy 0.1 Km/h
Units Km/h or Mph
Update rate 10 Hz
Maximum velocity 1000 Mph
Minimum velocity 0.1 Km/h
Resolution 0.01 Km/h

 

Distance
Accuracy 0.05% (<50 cm per Km)
Units Metres / Feet
Update rate 10 Hz
Resolution 1 cm
Height accuracy 10 metres     95% CEP**

 

Absolute Positioning
Accuracy 3m 95% CEP**
Update rate 10 Hz
Resolution 1 cm

 

Time
Accuracy 0.1s
Resolution 0.1s

 

Heading
Accuracy 0.1°
Resolution 0.01°

 

Power
Input voltage range 6 – 28 V DC
Current Typically 100 mA
 

 

Acceleration
Accuracy 1%
Maximum 4 G
Update rate 10 Hz
Resolution 0.01 G

 

Environmental and Physical
Weight 225 grams
Size 113 mm x 63 mm x 93 mm
Operating temperature -20°C to +50°C
Storage temperature -30°C to +80°C

 

Memory
Type SD Card
Recording time

Dependent on card capacity* 

* Approximately 1.1Mb per hour used

Definitions

** Circle of Error Probable (CEP): 95 % of the time the position readings will fall within a circle of the stated diameter