To configure VBOXs within a Subject Vehicle and 1 Target Vehicle using a Static Base Station for ACC, AEB, BSD or FCW tests, please follow the steps below:


Place one VBOX into each vehicle - one will be the subject vehicle and one will be the target vehicle.

Target Vehicle

  1. Connect VBOX Manager to the VBOX in the Target Vehicle.
     
  2. Enter the 'SETUP' menu of VBOX Manager.
     
  3. Select the 'VBOX' option and scroll to 'Log Rate'. Ensure that '100 Hz' is selected, if it is not, select the menu and choose the option.
 VBMAN ADAS Subject Contact Points.png  VBMAN ADAS Subject Contact Points.png
  1. Scroll to 'Dynamic Mode', select and then choose one of the following options:
    • If you are not using IMU integration, set the dynamic mode to 'Medium' and press to confirm, this Dynamics mode is best for ADAS tests.

      VBMAN ADAS Subject Contact Points.png
       
    • If you are using IMU integration, set the dynamic mode to 'High' and press to confirm.

      VBMAN ADAS Subject Contact Points.png
       
  2. Scroll to 'DGPS Rate' and select the appropriate settings for your radios.
 VBMAN ADAS Subject Contact Points.png  VBMAN ADAS Subject Contact Points.png  VBMAN ADAS Subject Contact Points.png

Note: To ensure that the VBOX receives the DGPS correction signal, the correct RS232 rate must be set. All Racelogic blue boxed radios use 115200 kbit/s, Satel grey boxed radios use either 19200 kbit/s or 38400 kbit/s.
 

  1. Scroll to 'DGPS Mode', select and then set to the same 2 cm mode that the Base Station is set to. For further info on RTK modes see RTK Configuration.

    VBMAN ADAS Subject Contact Points.png
     
  2. Return to the 'SETUP' menu by selecting 'Back'.

    VBMAN ADAS Subject Contact Points.png
     
  3. Select the 'ADAS' option and then choose '1 Target' as the ADAS mode, press to confirm.
 VBMAN ADAS Subject Contact Points.png  VBMAN ADAS Subject Contact Points.png
  1. Scroll to 'ADAS Function', select and then choose 'Target 1', press to confirm.

    VBMAN ADAS Subject Contact Points.png

Subject Vehicle

  1. Connect VBOX Manager to the VBOX in the Subject Vehicle.
     
  2. Repeat steps 2 – 8 in section ‘Target Vehicle' above.
     
  3. Scroll to 'ADAS Function', select and then choose 'Subject', press to confirm.

    VBMAN ADAS Subject Contact Points.png