The Tests menu can be used to configure brake test/lap timing settings.

Brake

Configure the start and end speed of non-trigger deceleration tests.
 

VB3iS VBOX Setup Tests Brake.png

 
Start/End speed

Defines the start/end speed at which the test will begin and finish, set as 100 km/h and 0 km/h by default.

Auto correct distance

This sets the speed sensor to use the nearest rounded 10 km/h speed when the trigger is activated. For example, if the trigger speed was 104 km/h, then 100 km/h would be the nominated start speed for the corrected brake stop distance.

Correct distance to

If the Auto option is not selected, the user is able to specify a speed value to correct all deceleration tests to.

Lap timing

Configure the lap timing settings, start/finish and split gates.
 

VB3iS VBOX Setup Tests Lap Timing.png

 
  1. Settings

VB3iS VBOX Setup Tests Lap Timing Settings.png

Gate width

This sets the width of any gates set in the software (25 m by default). It is a useful feature when two parts of a track run very close to each other, or the pit lane is next to the start/finish line, as lowering this value can stop the virtual line being triggered by the incorrect area of the circuit.

Retrigger time

This allows the user to set a number of seconds during which the brake trigger will not be reactive after having been pressed (1 s by default). This is to avoid trigger bounce during tests. 

CAN lap pulse width

This option controls the duration of the lap time and splits CAN pulse (1 s by default). Other lap timing CAN channels such as Lap Marker, start/finish crossing pulse or gate crossing pulse marker set to 2 s duration as default, or the highest analogue or digital pulse duration setting if greater. The CAN pulse width can not exceed any Digital or Analogue Lap pulse output duration. If an invalid setting is set, the software will not allow writing to unit. Hovering over the Write to unit button will report invalid setting.

Note: For a Lap Beacon Pulse to be output by VB3iS, ensure valid virtual gate(s) have been loaded.

Start finish/split to split time

Determines whether the 'Split Time' CAN channel is either the total lap time at split cross or the delta time between split lines.

 
  1. Virtual gates

VB3iS VBOX Setup Tests Lap Timing Gates.png
 

Use the ‘Load’ button to load a .spl, .dsf or .vbo file containing start/finish and split gates. The gates can also be saved in to a different format by selecting the 'Save' button, or removed using the 'Clear' button.